TH-5000 tensile machine - Tianhui Instrument

TH5000 series document.write('') rally machine document.write('') document.write('')document.write('')

A.document.write('') pull machine document.write('') ​​overview

Document.write('') ​​tensile machine document.write('') for rubber, plastic, plastic, film, textile, nylon, fiber, nanomaterials, polymer materials, composite materials, packaging tape, paper, wire and cable, Fiber optic cable, seat belts, belts, leather belts, footwear, tape, polymers, spring steel, bearing steel, stainless steel (
And other high hardness steels, castings, steel plates, steel strips, non-ferrous metals, automotive parts, alloy materials and other non-metallic materials and metal materials for stretching, compression, bending, tearing, 90° peeling, 180°
Peeling, shearing, adhesion, pull-out force, elongation at break, etc.

2.document.write('') rally machine document.write('') ​​host specification
A. High-precision American force transmission force sensor: 0~50KN.
The power accuracy is within ±0.5%.
B. Capacity segmentation: seven files in the whole process: × 1, × 2, × 5, × 10, × 20, × 50, × 100
High precision 24 bits A/D, sampling frequency 200Hz
Full force zui large resolution 1/1000,000
C. Power system: Japan Panasonic AC servo motor Panasonic AC drive + worm gear reducer + ball screw.
D. Control system: The Pulse Command control mode is used to make the control more precise and the speed control range is 0.001~360 mm/min.
The China Union Board adjustment has fast coarse adjustment and slow fine adjustment.
After the test, it will automatically return to the origin and automatically store.
E. Data transmission method: RS232 transmission
F. Display mode: UTM107 WIN-XP test software computer screen display.
G. Concise full-range first-class and precision full-range seven-speed power linear double correction system.
H. The luxury test interface software can realize the control mode such as fixed speed, positioning shift, fixed load (settable hold time), fixed load increase rate, constant stress increase rate, fixed strain increase rate and multi-level control mode. Test requirements.
I. Test space: test width approx. 400 mm (standard size)
175 mm walking space (without fixture) (standard size)
J. Full displacement: Encoder 2500 P/R, 4 times higher accuracy LINE DRIVE encoder anti-interference ability Strong displacement analysis 0.001mm. Small deformation: metal extensometer, analysis 0.001mm (optional)
K. Safety device: overload emergency stop device, upper and lower stroke limit device,
Leakage automatic power off system, automatic breakpoint stop function.
M. Manual control: Add wireless remote control or manual operation box. (need to buy)

Three.document.write ('') rally machine document.write ('') software features:
A. Test Standard Modular Function: Provides the user to set the test standard settings for the required application, covering GB, ASTM, DIN, JIS, BS, etc. Test standard specifications.
B. Sample data: Provide users to set all sample data, and once input data is permanently reused. The formula can be added to improve the test data fit.
C. Double report editing: Fully open user edits the report for testers to choose their favorite report format (the test program adds built-in EXCEL report editing function to expand the previous single professional report format)
D. Each length, power unit, and display digits are dynamically exchanged, and the power units are T, Kg, N, KN,
g, lb, deformation unit mm, cm, inch.
E. The curve curve scale automatically optimizes Auto Scale, which can make the graph
Zui good scale display. And can dynamically switch between real-time graphics during testing. Load-displacement, load-time, displacement-time, stress-strain load-2 point extension map, and multi-curve contrast.
F. The test results can be output in the form of data in the EXCEL format.
G. At the end of the test, it can be automatically archived and manually archived. After the test is completed, the zui power, upper and lower yield strength,
Hysteresis loop method, stepwise approximation method, non-proportional extension strength, tensile strength, compressive strength, arbitrary point-stretching strength,
Any point constant load extension, elastic modulus, elongation, peeling interval zui large value, zui small value, average value, net energy,
Foldback energy, total energy, flexural modulus, breakpoint displacement x% load, breakpoint load X% displacement, and so on.
Data backup: Test data can be saved on any hard disk partition.
H. Multi-language random switching: Simplified Chinese, Traditional Chinese, English.
I. The software has a historical test data demonstration function.

4.document.write('') rally machine document.write('') ​​attachment
A. document.write('') ​​Rally machine document.write ('') one year warranty and one Chinese operation manual.
B. Randomly give a standard document.write('') ​​rally machine document.write('') a set of fixtures (other fixtures to buy).
C. document.write ('') Rally machine document.write ('') dedicated test software.
D. One set of brand computers and one color printer

Five.document.write('') rally machine document.write ('') can test the project

(1) Ordinary test items: (normal display value and calculated value)

● tensile stress ● tensile strength

●Tear strength ● Elongation at break

●Fixed stress ●Constant elongation

●Constant stress value ●Tear strength

● Any point force value ● Any point elongation

●Extraction force ●Adhesion and peak value calculation

●Pressure test ●Shear peel force test

●Bending test ● Pulling force puncture test

( 2) Special test items:

Elastic Young's modulus

Definition: The ratio of the normal stress component to the normal strain in the same phase. To determine the coefficient of material stiffness, the higher the value,

The stronger the material.

2. Proportion limit: The load can maintain a proportional relationship with the elongation within a certain range, and the large stress of the Zui is the ratio limit.

3. Elasticity limit: the large stress of the material that can be withstood without permanent deformation.

4. Elastic deformation: After the load is removed, the deformation of the material completely disappears.

5. Permanent deformation: After the load is removed, the material remains deformed.

6. Yield point: When the material is stretched, the deformation increases and the stress does not change. This point is the yield point. The yield point is divided into upper and lower yield points.

Generally, the above yield point is used as the yield point.

Yield: The load exceeds the proportional limit and is no longer proportional to the elongation. The load will drop suddenly, and then for a while,

Ups and downs, the elongation changes greatly, this phenomenon is called yielding.

7. Yield strength: the load at which the permanent elongation reaches a certain value when stretched, divided by the original area of ​​the parallel portion.

The business of the income.

8. Spring K value: the ratio of the force component to the deformation in the same phase as the deformation.

9. Effective elasticity and hysteresis loss:

On the document.write('') ​​puller document.write('') , the specimen is stretched to a certain elongation or stretched to the specified speed at a certain speed.

When the load is measured, the percentage of the ratio of the work recovered when the sample is contracted and the work consumed during the stretching is determined to be effective.

Elasticity; the percentage of the ratio of the energy lost during elongation and contraction to the work consumed during elongation, ie

Loss for lag.

VI.document.write('') rally machine document.write ('') main counting indicator

A. Load weight: 10-50KN interval matching

B. Power resolution: 1/10000

C. Strength accuracy: ≤0.5%

D. Power magnification: 7-segment automatic switching

E. Displacement resolution: 1/1000

F. Displacement accuracy: ≤0.5%

G. Metal Extensometer Resolution: 1/1000

H. Metal extensometer accuracy: ≤0.5%

I. Large deformation extensometer accuracy: ± 1mm

J. Speed ​​range: 0.001-360mm/min (special test speed can also be customized according to customer requirements)

K. Walking space: 950mm (without gripper, special test space can also be customized according to customer needs)

L. Test width: 400mm (special test width can also be customized according to customer needs)

M. Use the power supply: ∮ 380V 50HZ.

N. Power: about 1.6KW

O. Machine size: about 660 × 720 × 2000 mm length × width × height.

P. Machine weight: about 430 kg.

Seven document.write('') rally machine document.write('') operation sector Eight document.write('') rally machine document.write('') test results Nine document.write('') rally machine document.write('') report at a glance

Medical protective masks refer to self-priming filter dustproof medical protective equipment that can filter particles in the air, prevent the spread of certain infectious microorganisms in the respiratory tract, and block droplets, blood, body fluids, secretions, etc.
Medical protective masks are masks made of one or more fabrics that have isolation effects on viral aerosols, virus-containing liquids, and so on. Under the respiratory airflow, it still has a barrier effect on viral aerosols, virus-containing liquids, etc., and when removed, the outer surface of the mask does not contact the human body, can filter particulates in the air, and block droplets, blood, body fluids, secretions, etc. . The use of medical masks includes adhesion testing, training, model selection, medical treatment and maintenance.
Composition and function: The Medical Protective Mask consists of a mask face and a tightening belt. The mask face is divided into three layers: inner, middle and outer. The inner layer is ordinary sanitary gauze or non-woven fabric. Propylene fiber melt-blown material layer, the outer layer is non-woven fabric or ultra-thin polypropylene melt-blown material layer. This high-efficiency medical Protective Mask is highly hydrophobic and breathable, and has a significant filtering effect on tiny virus-carrying aerosols or harmful fine dust, and the overall filtering effect is good.
The medical protective mask has a good fit with the wearer's face, can filter particles in the air, block pollutants such as droplets, blood, body fluids, secretions, etc., and can filter non-oily particles by more than 95% Personal protective equipment commonly used to deal with airborne diseases.
Product specifications: According to the national standard GB 19083-2003 "Technical Requirements for Medical Protective Masks", important performances of medical protective masks include filtration efficiency, adhesion, liquid barrier performance, comfort, hygiene, and biological safety tests.
Scope of application: Medical protective masks are better protective products. It is recommended to wear when there is serious environmental pollution or sudden medical infectious diseases (such as respiratory tract infectious diseases), to prevent the spread of viruses from patients or the environment to users.
Important indicators: including non-oily particle filtration efficiency and airflow resistance.
(1) Filtration efficiency: Under the condition of air flow (85 ± 2) L / min, the filtration efficiency of aerodynamic median diameter (0.24 ± 0.06) μm sodium chloride aerosol is not less than 95%.
(2) Tightness: The overall fit factor of the mask should not be less than 100.
How to use: How to wear a head mask
(1) Gently pinch the nose clip and place the mask on the face to ensure that it can cover the nose and mouth.
(2) The upper elastic band is fastened on the head to prevent air from entering.
(3) Tighten the lower elastic band around the neck.
(4) Be sure to fully open the mask to minimize the number of layers used during breathing.
How to wear earhook masks
(1) Pass the ear straps with both hands, place the nose clip on the upper part, and wear the mask on the nose and mouth
(2) The ear strap should be placed at the base of the ear and spread from head to toe, so that the folds of the mask are fully unfolded, which helps to cover the face to the greatest extent and minimize the number of layers required for breathing.
(3) Gently pinch the nose clip to prevent air from entering.

Medical Surgical Mask

Surgical Face Mask,Disposable Surgical Mask,Disposable Protective Mask,Surgical Face Mask Disposable

Guangzhou Aikangli Medical Technology Co., Ltd. , https://www.aikanli.com