Shrimp Infectious Muscle Necrosis Virus (IMNV) Nucleic Acid Detection Kit (One Tube Thermostat Fluorescence Method) Instruction Manual

Shrimp Infectious Muscle Necrosis Virus (IMNV) Nucleic Acid Detection Kit (One Tube Constant Temperature Fluorescence Method)

â—† Product Description

The animal disease detection series is based on a unique thermostated fluorescence detection technology that can amplify specific nucleic acid fragments of viruses in samples such as food and animal tissues, and judge the results by real-time amplification curves. This product is used for the detection of shrimp infectious muscle necrosis virus (IMNV) with a detection limit of 10 3 copies/μl viral genomic RNA .

â—† Product composition ( 96 test)

031071L III

Reagent

content

A-IMNV-I

22μL × 96 tubes

BI

90 μL × 2

RI

12 μL × 2

NG-I

50 μL × 3

PG-IMNV-I

50 μL × 2

â—† Applicable instruments

Dhelix-C, ESE Tube Scanner, Genie II, Deaou-308C and other constant temperature fluorescence detectors, ABI 7500, LightCycler480, CFX 96 and other fluorescent PCR instruments.

â—† Self-supplied supplies and instruments

1 Sterilize 1.5mL or 2.0mL centrifuge tube; 2 ice box; 3 pipette (0.1-2.5μL, 0.5-10μL, 10-100μL, 100-1000μL) and matching sterilization tips; 4 centrifuge; 5 vortex Rotary mixer; 6 metal bath

â—† Notes

1. This reagent has high detection sensitivity. In order to prevent pollution, the experiment is to be partitioned.

1) First zone: sample preparation zone.

2) The second zone: the template addition zone.

3) Zone 3: Amplification and product analysis zone.

★ It is best to physically isolate the partitions to avoid pollution caused by human factors.

2. Work clothes and latex gloves are worn during the experiment, and tools are used independently in different areas. Gloves and lab coats need to be replaced.

3. Strictly follow the operation steps, reagent preparation and sample loading steps, please operate in strict accordance with the instructions on the ice box.

4. The components in the reaction solution are sensitive to light and should be stored away from light . The reagent should be completely thawed before use, but repeated freezing and thawing should be avoided. It is recommended to centrifuge for 30 seconds before use.

5. After the reaction is completed, the expansion tube should be placed in a sealed bag and discarded. On the same day, the lid is opened and the aerosol is easily contaminated. It is forbidden to open the lid.

6. Do not mix different batches of reagents used within the validity period.

â—† Sample processing

Samples prepared by the SC/T 7103-2008 Aquaculture Animal Quarantine Sampling Technical Specification or other standards are prepared for use.

For detailed steps, please follow the standard operation or check the food safety software.

â—† Experimental operation

1. Template preparation (sample preparation area)

It is recommended to use the aquatic animal virus genomic DNA/RNA extraction kit series. The specific process is detailed in the product manual.

2. Add a template (template add area, placed in the ice box)

The required test number of the PCR tube containing the reaction solution was taken out, the reagent was completely thawed, and after thawing, the tube cover was opened and 0.8 μL of BI and 0.2 μL of RI were added to the bottom of each tube, and the tube lid was centrifuged for 1 min. Open the tube cover and add 2 μL of template along the wall of each tube, in the order of NG-I, sample template to be tested, PG-IMNV-I. After the PCR tube cover was capped, it was centrifuged for 3 min, and the PCR amplification reaction was immediately performed.

3. Amplification reaction (amplification and product analysis area)

1 The constant temperature instrument was reacted at 63 ° C for 45 min.

2 If a real-time PCR instrument is used, the fluorescent group is selected as FAM, the quenching group is selected as None, 63 ° C for 15 s, 63 ° C for 45 s as a cycle, and fluorescence signal is collected at 63 ° C for 45 s, 45 cycles.

For other instruments, please refer to the instrument manual for setting.

  • Result determination

1 The instrument automatically determines the result. If “positive” is displayed, the sample contains the infectious muscle necrosis virus (IMNV) of the shrimp; if “negative” is displayed, the sample does not contain the infectious muscle necrosis virus (IMNV) or low content of the shrimp. At the detection limit. For example, if the curve rises between 40min and 45min and the automatic interpretation result is negative, it may be due to the low sample content. It is recommended to enrich the sample or prolong the reaction time to 60min for review.

2 On the fluorescence quantitative PCR machine, the results were determined based on the presence or absence of the "S" type amplification curve. If there is an "S" type amplification curve, the sample contains shrimp infectious muscle necrosis virus (IMNV); if there is no "S" type amplification curve, the sample does not contain shrimp infectious muscle necrosis virus (IMNV) or content. Below the detection limit.

  • The result of the NG reaction tube showed "negative", and the result of the PG reaction tube showed "positive". The test result was valid, otherwise it was invalid. If the duplicate test results are still invalid, please contact technical support.

Office Safe Box

Document preservation is an indispensable and important link. There are many types of documents in the office, some are company financial data, some are employee personal data, some are contract agreements, etc. The office safe is a good choice to protect the safety of these files, and play a role in keeping and storing files.

Office safes produced by our company are made of high quality solid alloy steel with excellent anti-drilling and anti-smashing properties, equipped with solid locking bolts and thickened door panels to provide physical protection against forced entry.

This office safe of different sizes has different interior Spaces. Safes of 35cm and above are equipped with movable and adjustable shelves, multi-functional hooks and private inner cabinets, giving you more choice and more flexible storage space.

Our 25cm height and above safes feature a dual alarm system that automatically activates after 3 consecutive incorrect password or fingerprint input and vigorous vibration, with an alarm sound of more than 70 decibels for 60 seconds, and you can hear it in every corner of your home.



Office Fingerprint Safe Box,Office Electronic Safe,Wholesale Office Safebox,Documents Safebox

Hebei Hupai Aodi Cabinet Industry Co.,Ltd. , https://www.hupaiaodi.com