How to use IKA multi-point magnetic stirrer correctly

IKA multi-point magnetic stirrer, mainly in the following paragraphs: RT5, RT10, RT15, RO5 , RO10, RO15 magnetic stirrer. These six IKA multi-point magnetic stirrers have the following common features:

1. With multiple stirring points, it can mix and mix multiple samples at the same time;

2. Synchronous stirring at each mixing point, constant speed, suitable for synchronous mixing applications;

3. Low-level structure design, occupying a small space;

4. Applications: sample dissolution, media or chemical reagent preparation, and titration tests.

Ika RO10 multi-point magnetic stirrer

The magnetic stirrer is a basic laboratory instrument that everyone is very familiar with. The magnetic stirrer has a wide range of applications and involves many fields, which brings a lot of convenience to our experimenters, but the operation and use of magnetic stirring. When we have some simple maintenance, we still need to know. Labee will introduce it to you.

1. It is best not to let the instrument work without heating liquid.

2. Check the grounding before operating the magnetic stirrer to ensure that it can be operated after completion.

3, in order to ensure that the instrument is not damaged, usually the inside of the instrument will be placed with insulating materials, so we may find a little white smoke or pungent smell when we use the ika multi-point magnetic stirrer for the first time. The normal phenomenon is not a product quality problem, just keep it ventilated.

4, ika multi-point magnetic stirrer inside the device is limited by heat, so must be considered when heating. The best way to do this is to ensure that the machine is not heated only, and that the state of the motor is changed to a rotating state, so that the magnetic stirrer can be protected to the utmost extent.

5. After the heating work is completed, be sure to turn off the heat first. After a few minutes, the temperature has been dissipated and the stirring is turned off.

6, to ensure that the ika multi-point magnetic stirrer operating environment is dry. In a humid environment, the instrument is prone to leakage and other phenomena. This is why the instrument must be grounded. If the instrument is found to be very wet before use, be sure to dry it with hot air.

7, must be careful during the operation, do not get burned, because the general temperature is relatively high.

8. For safety reasons, a fuse is provided on the back of the instrument. When the device is still not working, it can be checked whether it needs to be replaced.

When you use ika multi-point magnetic stirrer , as long as you pay attention to the correct use and care, Lebe believes that it will extend the service life of the laboratory equipment, better let these instruments work for us, and also save everyone's cost. (Currently cost control is also very important).